YYL serie gas (oil) fired organic heat carrier boiler
Features:
1. Obtain low pressure high temperature heat agent, adjustment convenience, suppling heat equit, for meeting exact process termperature.
2. Liquid phase circulating supply heat, no condensation discharge heating loss, supplying heating system high heating efficiency.
3. Actuating medium heating and discharge heat and temperature up-down for volum changed, the inner of system has compensation treatment measures.
4. The air, water and others volatile matters are in the actuating medium which have seriously treatment measures before supplying heat circulating.
Applications:
1. Chemical industrial----grease chemical, polymerization indurstrial, reaction tank, distillation, concentration.
2. Plastic industrial----plastic foamed, squeeze the finalize the design
3. Textile industrial----Resing finishing tenter, dyeing machine, drying room, high temperature machine, roll machine.
4. Rubber industrial----baking
5. Food industrial----steam cook, drying, plant oil refine.
6. Forest profuct industrial-----temperature setting of the plywood, fibreboard.
7. Paper industrial----mutil layes carboard,oven drying, drying of packing carton.
8. Others---heating, coating condensation, drying of metal plate path, distillation, reduction, concentration, dehydration of medicine industrial.
Technic parameter
Model
|
YYL 180Y(Q)
|
YYL 300Y(Q)
|
YYL 350Y(Q)
|
YYL 600Y(Q)
|
YYL 850Y(Q)
|
YYL 1200Y(Q)
|
YYL 1400Y(Q)
|
YYL 1800Y(Q)
|
YYL 2400Y(Q)
|
YYL 3000Y(Q)
|
Rated power (kw)
|
180
|
300
|
350
|
600
|
850
|
1200
|
1400
|
1800
|
2400
|
3000
|
Rated Power (Wkcal/H)
|
15
|
25
|
30
|
50
|
75
|
100
|
120
|
150
|
200
|
250
|
Rated operating pressure (MPa)
|
0.8
|
0.8
|
0.8
|
0.8
|
0.8
|
0.8
|
0.8
|
0.8
|
0.8
|
0.8
|
Rated Operation Temperature (°C)
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
Inner of boiler oil quantity M3
|
0.153
|
0.21
|
0.25
|
0.4
|
0.52
|
1.08
|
1.35
|
1.48
|
2.1
|
2.3
|
Oil circulation quantity M3/H
|
20
|
40
|
40
|
80
|
80
|
100
|
100
|
100
|
200
|
200
|
All system setting machine capacity KW
|
Oil
|
11
|
14
|
14
|
22
|
22
|
40
|
40
|
40
|
66
|
70
|
Gas
|
11
|
17
|
17
|
27
|
40
|
40
|
42
|
45
|
70
|
70
|
Fuel
|
light oil, heavy oil, nature gas, city using gas
|
|
|
|
Whole size(M)
|
L
|
0.9
|
1.1
|
1.25
|
1.3
|
1.57
|
1.8
|
1.86
|
2
|
2.2
|
2.4
|
M
|
0.9
|
1.1
|
1.25
|
1.3
|
1.57
|
1.8
|
1.86
|
2
|
2.2
|
2.4
|
H
|
1.83
|
1.9
|
2.5
|
3.05
|
3.35
|
3.79
|
4.3
|
5.21
|
5.84
|
6.54
|
Boiler total weight (T)
|
1.32
|
1.73
|
2.59
|
3.58
|
4.29
|
7.35
|
7.58
|
8.78
|
11.4
|
14.5
|
|